Pendant control station PKS-3\W01
Pendant control stations PKS-3 PKS-2
PKS-3\W01
EAN:
1 Emergency pushbutton
1 Pushbutton with 1 NO contact
1 Pushbutton with 1 NO contact
1 Pushbutton with 1 NO contact
1 Pushbutton with 1 NO contact
Rated insulation voltage Ui | 500 V |
Rated continuous current Iu=Ith | 10 A |
Rated operational current Ie for AC-15 | 2.5 A (230 V) 1.6 A (400/500 V) |
Rated operational current Ie for AC-13 | 4 A (24 V) 1 A (110 V) 0.25 A (220 V) |
Switch short-circuit protection | 10 A (fast fuse link) 1 kA (prospective short circuit current for Ue=500 V) |
Mechanical endurance | 0.3 mln (transposition cycles) |
Electrical endurance | 0.2 mln (at rated switching voltages and currents) 1.0 mln (switching cycles) - up to 80 VA (for AC electromagnets) - up to 10 W (for DC electromagnets) |
Frequency of switching | up to 3600 h-1 |
Ambient temperature | -40 ... +70°C (work) -40 ... +70°C (storage) |
Vibration test (acc. to PN-EN 60068-2-6) | 2...13, 2...100 Hz (frequency) ± 1 mm (amplitude) ±0.7 g (acceleration) |
Shock test (acc. to PN-EN 60068-2-27) | 15 g (peak acceleration) 11 ms (impulse duration) |
Damp heat cyclic test (acc. to PN-EN 60068-2-30) | 55°C (ambient temperature) 95% (relative humidity) |
Salt mist cyclic test (acc. to PN-EN 60068-2-52) | severity 1 |
Protection level | IP65 |
Wire gauge | 2× 1...2.5 mm² (solid) 2× 0.75...1.5 mm² (stranded) |
Working position | any |
Terminal marking | PN-EN 50013 |
Compliance with the standard | PN EN 60204-32 PN EN 60947-1 PN-EN 60947-5-1 PN-EN 60947-5-5 2006/42/EC - Machinery Directive 2014/35/UE - Low-voltage Directive |
Weight | 340 g |